Page view 11
The connection of the cooktop to the gas
pipe network or gas cylinder must be made
by means of a rigid copper or steel pipe
with fittings complying with local regula-
tions, or by means of a continuous surface
stainless steel hose complying with local
regulations.
If you see any abnormalities do not re-
pair the pipe, contact local After Sales
Service (refer to the Service chapter).
The connection must be installed correctly,
fixed into hob connection pipe. Otherwise it
will cause leakage of gas
Warning! Once the installation is
complete, check the perfect seal of
every pipe fixing. Use soapy water, never
flame.
Electrical connection
Before connecting, check that the nominal
voltage of the appliance stated on the rat-
ing plate, corresponds to the available sup-
ply voltage. Also, check the power rating of
the appliance and ensure that the wire is
suitably sized to suit the appliance power
rating (refer to the Technical data chapter).
The rating plate is located on the lower cas-
ing of the hob.
The appliance is supplied with a connection
cable. This has to be provided with a prop-
er plug, able to support the load marked on
the identification plate.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you in-
stall a double pole switch between the ap-
pliance and the electricity supply, with a
minimum gap of 3 mm. between the switch
contacts and of a type suitable for the re-
quired load in compliance with the current
rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
temperature 90 °C higher than the room
temperature. The brown (or black) phase
cable (fitted in the terminal block contact
marked with "L") must always be connected
to the network phase.
1
2
Replacement of the connection cable
Warning! The replacement of the
connection cable requires the specific
equipment of a technician.
In this case, only cable type H05V2V2-F
T90 must be used. The cable section must
be suitable to the voltage and the working
temperature. The yellow/green earth wire
2
must be approximately 2 cm longer than
the brown (or black) phase wire
1
(previ-
ous figure).
Gas setting conversion
This model is designed for use with
natural gas but can be converted for
use with butane or propane gas providing
the correct injectors. The injectors not sup-
plied with the appliance have to be or-
dered from After Sales Service (refer to the
Service chapter).
For data concerning injector replacement,
refer to the chapter Technical data
Warning! Conversion or replacement
can only be performed by a registered
installer.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
ENGLISH 12