Page view 20
and the valve filter are blocked (see
chapter "Troubleshooting" for more details).
Proceed as follows:
1
2
3
Turn off the water
tap.
Unscrew the hose
from the tap.
Clean the filter in
the hose with a stiff
brush.
Screw the hose back onto the tap. Make
sure the connection is tight.
Unscrew the hose
from the machine.
Keep a rag
nearby because
some water may
flow.
Clean the filter in
the valve with a
stiff brush or with
the piece of cloth.
45°
20°
Screw the hose
back to the
machine and make
sure the
connection is tight.
Turn on the water
tap.
Frost precautions
If the appliance is installed in an area
where the temperature can be less than 0
°C, remove the remaining water from the
inlet hose and the drain pump.
Do this procedure also when you
want to do the emergency drain.
1. Disconnect the mains plug from the
mains socket.
2. Remove the water inlet hose.
3. Remove the drain hose from the rear
support and unhook it from sink or
spigot.
4. Put the ends of the drain and inlet hose
in a container. Let the water flow out of
the hoses.
5. When no more water flows, install the
inlet hose and the drain hose again.
Caution! Make sure that the
temperature is more than 0 °C
before you use the appliance
again. The manufacturer is not
responsible for damages caused
by low temperatures.
Troubleshooting
Warning! Refer to Safety
chapters.
Introduction
The start of the appliance does not occur or
it stops during operation.
ENGLISH 21
Page view 20