IKEA HB 530 WF Instruction for Use Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
ENGLISH 14
- loosenscrewtoincreasetheameheight
(+).
Theadjustmentmustbeperformedwiththe
tapinminimumgassettingposition(small
ame).
- Theprimaryairoftheburnersdoesnot
needtobeadjusted.
- Atthisstage,lightuptheburnersand
turntheknobsfrommaxposition
tominimumposition tocheckame
stability.
Uponcompletionofadjustment,reseal
theworksurfaceusingsealingwaxoran
equivalentmaterial.
GB
REFERENCETOLOCAL
REGULATIONS
Provisionforventilation
Theroominwhichtheapplianceisinstalled
musthaveanairsupplytocurrentB.S.5440
-Part2standards.
Allroomsrequireapermanentventin
additiontotheopenablewindow.
Ifthereareotherfuelburningappliancesin
thesameroomB.S.5440-Part2should
beconsultedtodeterminetheairvent
requirements.
Iftheapplianceisinstalledinacellaror
basement,itisadvisabletoprovidean
airventof65cm,irrespectiveoftheroom
volume.
GasSafetyRegulations
Thelawrequiresthatallgasappliances
areinstalledbycompetentpersonsin
accordancewiththecurrentgassafety
regulations.Failuretoinstallappliances
correctlymayleadtoprosecution.Itisin
yourowninterest,andthatofsafety,to
ensurethatthelawiscompliedwith.The
hobshouldbeinstalledinaccordancewith
theGasSafety(InstallationandUse)
Regulations,theBuildingRegulations
issuedbytheDepartmentoftheEnvironment
andtheBuildingStandard(Scotland)
(Consolidation)Regulations,issuedbythe
ScottishDevelopmentDepartment.
IntheG.B.,CORGIregisteredinstallerswork
tosafestandardsofpractice.