Page view 28
Emergency emptying out
If the water is not discharged, proceed as
follows to empty out the appliance:
unplug the appliance;
turn off the water tap;
if necessary, wait until the water has
cooled down;
open the filter door;
place a container on the floor below the
recess of the filter;
press the two levers and pull forward the
drainage duct to let the water flow out;
when the container is full of water, put
the drainage duct back again and empty
the container. Repeat this operation until
water stops flowing out;
if necessary clean the filter (refer to the
section ‘Cleaning the drain filter’ );
close the drain pump door.
When you drain the water with the
emergency drain procedure, you must
activate again the drain system:
put 2 litres of water in the main wash
compartment of the detergent dispenser;
start the programme to drain the water.
The dangers of freezing
If the appliance is installed in a place where
the temperature could drop below 0°C,
proceed as follows to remove any water
remaining inside the appliance:
unplug the appliance;
turn off the water tap;
unscrew the water inlet hose from the
tap;
empty the filter as described in the
‘Emergency emptying out’ paragraph;
when the filter is empty, install the water
inlet hose again.
Warning! Make sure that the
temperature is more than 0° C
before you use the appliance
again.
The manufacturer is not
responsible for damages caused
by low temperatures.
Troubleshooting
Warning! Refer to Safety
chapters.
Introduction
The start of the appliance does not occur or it stops during operation.
First try to find a solution to the problem (refer to the table). If not, contact the Authorised
Service Centre.
With some problems, the acoustic signals operate and the display shows an alarm code:
- The appliance does not fill with water.
- The appliance does not drain the water.
- The appliance door is open or not closed correctly.
Warning! Deactivate the appliance before you do the checks.